Solving Smart Meter Signal Issues

Case Study: Solving Smart Meter Signal Issues in a Rural Farmhouse in Bolton-by-Bowland, Ribble Valley

The Problem: Smart Meter Not Communicating With Supplier

Many rural properties across the Ribble Valley and wider Lancashire area face challenges when it comes to smart meter connectivity. In this case, a traditional stone-built farmhouse in Bolton-by-Bowland was struggling to connect its Octopus Energy smart meter to the network.

Despite a technician from Octopus confirming a strong external signal, the signal couldn’t penetrate the thick stone walls of the property, and the smart meter’s location—under the stairs and near the centre of the house—only compounded the issue.

The result?

  • The smart meter couldn’t “talk back” to the supplier
  • The customer was stuck on estimated billing, being charged a shocking £22 per day for electricity use
  • No access to live usage data or intelligent tariff options

Our Expert Solution: Installing a Smart Meter Signal Booster Aerial

As specialists in aerial and signal distribution systems, the team at Handley Aerials was called in to assess the issue. After a detailed site survey, we determined that the only way to overcome the internal signal blockage was to install an external aerial tuned to the 420MHz frequency band—which is commonly used by smart meters to communicate with the DCC (Data Communications Company) network.

Our step-by-step approach:

  1. Signal Testing and Site Analysis
    Using our diagnostic tools, we confirmed that there was indeed adequate signal reception outside the property—but significant attenuation inside due to the wall thickness and meter location.
  2. Antenna Selection
    We chose a specialist 420–430MHz band aerial, known to be effective at receiving smart meter network signals in rural areas.
  3. Strategic Aerial Placement
    The aerial was mounted externally in a position with optimal line-of-sight to the nearest smart meter network mast, avoiding local terrain obstructions and minimising cabling distance.
  4. Low-Loss Coaxial Cable Run
    We installed a high-quality, low-loss coaxial cable from the aerial to the location of the smart meter, carefully routing it through the property without damage or disruption.

Passive Termination Array
At the smart meter end, we terminated the cable into a passive array, positioned as close as possible to the meter’s comms module to enhance signal pickup without needing external power or amplification.

The Result: Full Smart Meter Connectivity & Lower Bills

Once the installation was complete, Octopus Energy returned to commission the meter. They were impressed to find that the smart meter was now successfully communicating with their systems—without any further need for signal boosters or alternative solutions.

The impact for the homeowner:

  • Smart meter fully commissioned
  • Live usage data available
  • Access to cheaper tariffs

Daily electricity charge dropped from £22 to just £5—an immediate and substantial saving

Why This Matters

This case highlights a growing problem in rural areas and older buildings, where smart meter rollout is being hampered by signal issues. It also showcases the value of working with a knowledgeable, technically proficient aerial expert who understands both the signal environment and the smart meter infrastructure.

At Handley Aerials, we’re more than just a TV and satellite installer. We’re experts in:

  • Smart Meter Signal Boosting
  • Low-frequency aerial installation (400–470MHz)
  • Custom signal distribution in difficult environments

Rural property technology solutions